Remanufacturing Process - APS Petroleum 1-800-633-2420

Go to content
Every pump or dispenser goes through a thorough inspection, re-work, and testing to ensure it works perfectly when installed at your site.  We make sure of this by performing the following procedures:

1.Disassemble and replace worn parts.
2.Degrease and prime frame.
3.Check wiring and bring up to OEM specifications.
4.Replace worn gaskets, seals, and o-rings.
5.Install rebuilt meter(s) in most units.
6.Test electronic circuit boards and replace if necessary.
7.
Install new filters.
8.Liquid pressure test each unit.
9.Check for leaks.
10.Check meter for calibration.
11.Replace instruction and price decals.
12.Replace outer panels with APS manufactured parts.
13.Crate or prepare unit for shipping.
14.Back each product with a 1-year parts warranty.
Back to content